Search
Close this search box.

How to solve the interference of automatic gates

interference of automatic gates

Table of Contents

The automatic gate is a real convenience in everyday life, but how to solve an inconvenient situation such as that of interference with automatic gates? Here is the guide that will help you.

Automatic gate interference: understanding the origin of the problem

Automatic gates have an electric control unit to which different inputs are sent, but the signal that can have the most problems is the one transmitted by the remote control to the central motor, because it is on a frequency used by many devices.

The set of all electronic equipment traveling along the same frequency very frequently creates problems for your gate automation.

So, you have installed an automation for gates to finally avoid continuously getting off the car and manually opening and closing the gate even in the rain, but you have found yourself in the condition of not being able to operate the mechanism because there is interference at the automatic gate?

In this case you certainly have a problem with an external interference of radio waves that disturbs the transmission frequency of the remote control which is unable to correctly send the signal to the gate’s electrical control unit.

A real inconvenience but that can be solved in a short time. It is a classic difficulty that occurs especially in densely populated areas such as apartment buildings, where there are many radio devices that operate on the same frequency. The waves overlap each other and automatically create interference on the automatic gates.

The frequency most prone to this type of problem is 433.92 MHz, because it is occupied by many transmitters that are used every day, such as remote controls for cars and for gates and wireless alarms.

Other causes that can limit the wave are the presence of telephone repeaters and tower cranes on construction sites.

The interference problem not only causes the automatic gate to not respond correctly following the command, but in many cases, by continuously receiving signals of the same 433.92 MHz wave, it could open and close continuously during the day and night, also weighing on costs. of the current.

Automatic problem gate: the solution to interference

When the automatic gate does not open and does not close correctly, there is always an interference problem.

Are you thinking of removing the automation for gates and giving up the convenient opening via radio control, why are you tired of this discomfort?

Do not make this mistake because it is very easy to solve the problem of interference with automatic gates.

So what to do when the automatic gate has problems? Simple, just change the transmission frequency between the transmitter, in this case the radio control, and the receiver, that is the frequency card of the gate operator.

It is therefore necessary to move from the 433.92 MHz frequency to a less crowded band such as 868.35 MHz.

In the condition in which an interference on the automatic gates disturbs the opening and closing mechanism, an automation card must be installed that receives the 868.35 MHz frequency, and then all the radio controls in use are replaced with those with the new frequency and reconfigure them.

Once this step has been carried out correctly, the entire opening and closing system of the automatic gate will no longer have any interference problems.

VDS Automation: our control devices

For each type of frequency VDS Automation has created a series of control devices that adapt to the different types of automatic gate, offering the possibility of convenient opening and closing of your automatic gate.

Our production of control equipment is divided into:

  • Control equipment for swing gate automations;
  • Control equipment for automations with sliding doors, barriers and overhead doors;
  • Control equipment for shutters;
  • Control equipment for towing and tilting automations;
  • Accessories for control equipment such as radio receivers and modules;
  • Loops and detectors for the correct management of automation;
  • Transmitters and programmers for automation;
  • Transformers for gate automation.

All VDS Automation equipment are designed and built to be highly performing and specific for each type of gate automation.

Our company has been operating exclusively in the gate automation sector for over thirty years, producing all the mechanisms and accessories that are essential for the proper functioning of the entire system.

Our production boasts the quality of Made in Italy because we only use Italian raw materials and work in our headquarters, where every single product is promptly tested before being put on sale.

The safety and quality of our products are our strengths, on which we base the entire process of designing and manufacturing our gate automations.

We also offer you the assistance service for all problems. Our specialized operators will come directly to the site to solve them as quickly as possible.

Do not give up the convenience of an electric gate when you have an interference problem because the solution exists and it is simple to implement.

If you want to receive more information or request a quote on our control equipment, contact us by writing an e-mail to info@vdsautomation.com, or by calling 085 4971946. We are waiting for you!

Do you want to automate your gate?

Fill out the form and request information

Contact us for more information